Mod hand synthes.

The Variable Angle LCP™ Forefoot-Midfoot System offers a wide range of low-profile plates with variable angle (VA) screw placement and compression system designed within the plates to help minimize additional soft tissue dissection. Available in stainless steel and titanium. Product Specifications.

Mod hand synthes. Things To Know About Mod hand synthes.

About This Product. The system consists of three plate types, each one available in left and right version: Lateral Plate. Shaft Plate. Medial Plate. The VA LCP Clavicle Plates are made up of stainless steel and titanium alloy. The holes of the plates accept 2.7 mm cortex screws, 2.7 mm VA locking screws and 2.7 mm metaphyseal compression screws.The MatrixRIB™ Fixation System offers stable fixation of normal and osteoporotic ribs combined with minimally invasive technique. The system consists of precontoured locking plates, locking screws, intramedullary splints, and custom instruments for the fixation and stabilization of the chest wall. 1. Get in Touch with a Sales Consultant.Apply your e-signature to the page. Click Done to save the adjustments. Save the papers or print your PDF version. Send instantly towards the receiver. Take advantage of the quick search and innovative cloud editor to generate an accurate Inventory Control Form Synthes Modular Hand System. Clear away the routine and create papers on the internet!Synthes Modular Hand System - 105.200 - Stainless Steel set. SKU: 105.200-modular-hand-3 Categories: Other Orthopedic Trauma Sets, Synthes Hand Modular Sets, Synthes Other Trauma Sets. Description. Additional information.March 15, 2018. Part 3 of 5: Watch this video to learn more as Dr. Fischer demonstrates surgical techniques using the DePuy Synthes Variable Angle Locking Hand System in …

Fig. 1 1. Page 30 Slide the drive unit and coupling over the Kirschner wire. Grasp the wire by pulling the lever toward the handpiece and press both triggers (reverse) simultaneously to remove the wire from the bone. Fig. 3 Synthes Trauma Recon System Instructions for Use...Synthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J9514-C 9/12 Inventory Control Form 1.5 mm LCP Modular Mini Fragment System 1.5 mm Locking Screws, self-tapping, with T4 Stardrive recess LENGTH LENGTH 02.214.006 6 mm 02.214.007 7 mm …

Synthes 3.2mm Percutaneous Drill Bit QC/ 300mm/ Calibrated 324.212 $ 125.00 Add to cart; Synthes 6.5mm Tap Calibrated To 150mm / 197mm O.L 311.66 $ 150.00 Add to cart; Medtronic Surgical Midas Rex Attachment 9BA40D IN DATE! $ 75.00 Add to cart; Depuy Surgical Hand Fracture Instrument Set W/ Case Synthes Surgical Distal Radius Fixator Instrument ...

components necessary for the DePuy Synthes Variable Angle Locking Hand System. DePuy Synthes Companies are dedicated to improving patient care. System Snapshot x Extensive system of anatomically precontoured plates x First to the market with 1.3 mm locking screws for hand plating1 x Forceps that aid in fracture reduction and lag screw applicationFeatures & Benefits. Power Module designed for increased lifetime and cost effectiveness 1. Intelligent design allowing instant battery capacity and function check. Comprehensive range of drilling, reaming and sawing …UNIUM. ™. System. 05.001.601 , 05.001.611 , 05.001.602 ... Designed with a focus on ergonomics, reliability and efficiency, so the focus remains on the patient, without distraction. One power tool system for use in trauma, sports medicine, spine and cardiothoracic surgery.The Stryker Hand Plating module houses the VariAx Hand Locking and Profyle Hand Systems which offer the benefits of a comprehensive range of variable angled locking … Part 1 of 5: Watch this video to learn more as Dr. Fischer and Dr. Richard demonstrate surgical techniques using the DePuy Synthes Variable Angle Locking Hand System in this five-chapter series. In this video, they provide an overview of the system and focus on the comprehensive instruments available in the set. This content is intended for Health Care Professionals in the United States. To ...

Make these fast steps to change the PDF Synthes mini fragment set inventory sheet online for free: Sign up and log in to your account. Log in to the editor using your credentials or click Create free account to evaluate the tool’s capabilities. Add the Synthes mini fragment set inventory sheet for editing.

The MatrixRIB™ Fixation System offers stable fixation of normal and osteoporotic ribs combined with minimally invasive technique. The system consists of precontoured locking plates, locking screws, intramedullary splints, and custom instruments for the fixation and stabilization of the chest wall. 1. Get in Touch with a Sales Consultant.

Orthopaedic Foot Instruments Surgical Technique DePuy Synthes 1 MR Information The Orthopaedic Foot Instruments have not been evaluated for safety and compatibility in the MR environment. It has not been tested for heating, migration or image artifact in the MR environment. The safety of the Orthopaedic Foot The modular CMFD system offers a low-profile stable distraction construct without unintentional reversal combined with intraoperative flexibility and ease-of-use during application and removal. 1-3. Anti-reversal detent clip is contained within distractor body for a consistent, smooth profile that helps reduce impact to soft tissue. 1,4.Synthes GmbH Eimattstrasse 3 CH-4436 Oberdorf www.synthes.com 0123 Ö036.000.206öAAkä Setlist Modular Trays TEN System 01.009.011 Modular TEN Instrument Tray, size 1/1, with Contents 68.009.001 Modular Tray, size 1/1, for TEN Instruments, without Contents 359.217 Cutter for TEN 1 359.213 Awl for TEN 1 359.219 …The Large External Fixation System uses a modular construction to allow flexibility and a variety of forms of assembly to externally stabilize long bones, pelvic ring fractures, arthrodesis, and osteotomies. The system combines the Modular Knee Bridge and the Pelvic Frame. Product Specifications. 105.200/ Modular Hand System 145.200 (stainless steel or titanium) or 01.111.120/ Modular Mini Fragment LCP Instrument 01.111.140 and Implant Set (stainless steel or titanium) 1 Reduce fracture Instruments 292.10/ 1.0 mm Kirschner Wire, trocar point 492.10 (stainless steel or titanium) or 292.50* 1.0 mm Kirschner Wire, trocar points on

synthes.vo.llnwd.net The following tips can help you complete Synthes Modular Hand Inventory Control Form quickly and easily: Open the document in our feature-rich online editing tool by clicking on Get form. Fill in the requested fields that are colored in yellow. Hit the green arrow with the inscription Next to move on from field to field. Synthes Mini Fragment Instrument and Implant Set with Self-Tapping Screws (105.488) Instrumentation Catalog # Description 310.11 1.1 mm Drill Bit, Quick Coupling, 60 mm (2) 310.15 1.5 mm Drill Bit, Quick Coupling, 85 mm (2) 310.19 2.0 mm Drill Bit, Quick Coupling, 100 mm (2) 310.26 2.7 mm Drill Bit, Quick Coupling, 100 mm (2)The Variable Angle (VA) LCP Clavicle Plate 2.7 System is the next generation of internal fixation for the clavicle designed to treat medial, lateral, and shaft fractures ( Fig 1 ). The system was created in response to clinical challenges in the current treatment of fractures of the clavicle and is available in both stainless steel and titanium ...

Gorilla Tags are a popular type of RFID tag that can be used for a variety of purposes, from tracking inventory to providing access control. While they are typically programmed wit...The Mini External Fixator is made up of the following key components: Holding clamps available in 2 sizes. 3.0 mm / 3.0 mm and 3.0 mm / 4.0 mm connecting clamps. Threaded, trocar tip Kirschner wires available in 2 sizes. Angled connecting bar.

Part 2 of 5: Watch this video to learn more as Dr. Fischer and Dr. Richard demonstrate the approach when using the DePuy Synthes Variable Angle Locking Hand System in this five-chapter series. In this video, they focus on explaining the specialty plates available in the set. This content is intended for Health Care Professionals in the United States. To view educational resources, visit <a ...519.970 Oil Dispenser with Synthes Special Oil, 50 ml 05.001.229 T-Handle for fixing of saw blades Vario Cases and Washing Baskets 68.001.595 Vario Case, size 1/1, for Trauma Recon System with two Inserts, without Lid, without Contents 68.001.592 Vario Case, size 1/2, for Trauma Recon System Battery Handpiece,About This Product. The system consists of three plate types, each one available in left and right version: Lateral Plate. Shaft Plate. Medial Plate. The VA LCP Clavicle Plates are made up of stainless steel and titanium alloy. The holes of the plates accept 2.7 mm cortex screws, 2.7 mm VA locking screws and 2.7 mm metaphyseal compression screws.... synthes mini fragment set inventory sheet. synthes mini fragment surgical technique synthes titanium mini frag lcp mini frag synthes mod mini inventory synthes ...8 | Hand 12. – 23. Æ www.medartis.com Plate Bending If required, plates can be bent with the plate bending pliers (A-2040). The plate bending pliers have a pin to protect the plate holes during the bending process. The pin fits all 1.2 / 1.5 and 2.0 / 2.3 APTUS Hand plates. Notice While bending, the plate must always be held at two adjacentAdds Basic female Synths. adds Modern Gen2's with uniforms (includes black textures). Adds new Gen2X's with their own part human part robot outfits. Adds Gen3 Operatives and Agents with their own outfits. Everyone gets random vanilla wigs for variety. Update - Coursers - Appear more in missions - lite Ver - low level Ver.Implants Date: Hospital: Surgeon: Procedure: Case Information (eg, Case ID): MODULAR MINI FRAGMENT LCP® SYSTEM 2.0 mm, 2.4 mm and 2.7 mm Implants Inventory Control FormSynthes Complete System Mod. Electric Pen Drive. Complete System for Traumatologie as well as for Hand,- Foot, Spine, Maxillofazial and Neuro-Surgery. Artikelbeschreibung: Basic Console. Electric Pen Drive ( 60.000 rpm ) Handpiece for Electric pen drive. Drill chuck. Synthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J10176-B 3/13 2.4 mm/2.7 mm Titanium VA-LCP First MTP Fusion Plates Small Inventory Control Form 2.4 mm/2.7 mm Titanium VA-LCP Forefoot/Midfoot Plating System 04.211.230 0° right 04.211.231 0 ... FREE TRIAL. Learn the Internal fixation of middle phalangeal (P2) fracture using Synthes compact hand set surgical technique with step by step instructions on OrthOracle. Our e …

The Large External Fixation System uses a modular construction to allow flexibility and a variety of forms of assembly to externally stabilize long bones, pelvic ring fractures, arthrodesis, and osteotomies. The system combines the Modular Knee Bridge and the Pelvic Frame. Product Specifications.

Handy tips for filling out Synthes mod hand inventory online. Printing and scanning is no longer the best way to manage documents. Go digital and save time with signNow, the best solution for electronic signatures.Use its powerful functionality with a simple-to-use intuitive interface to fill out Mod hand synthes inventory control form online, e-sign them, and …

The AOTK approved Variable Angle Locking Hand System is the next generation of small implants for the hand consisting of plates that are anatomic, both fracture and procedure-specific and available in stainless steel and titanium. The system was designed to address clinical challenges faced in the current fixation of fractures and osteotomies and …The OsteoMed® Hand Plating System features instrumentation and low-profile implants designed specifically for treating hand trauma. Fracture Solutions OsteoMed Hand Plating System OsteoMed products Modules Distal Phalanges Middle Phalanges Proximal Phalanges Metacarpals and Carpals 1.2 mm 1.6 mm 2.0 mm 2.4 mm Offset Grid Plate …Synthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J10176-B 3/13 2.4 mm/2.7 mm Titanium VA-LCP First MTP Fusion Plates Small Inventory Control Form 2.4 mm/2.7 mm Titanium VA-LCP Forefoot/Midfoot Plating System 04.211.230 0° right 04.211.231 0 ...Find many great new & used options and get the best deals for Synthes Titanium Modular Mod Hand System Orthopedic Trauma at the best online prices at eBay! Free shipping for many products! ... item 3 Synthes Modular Hand System Synthes Modular Hand System. $5,000.00. item 4 Synthes Battery Handpiece, Modular, for Trauma Recon System …March 15, 2018. Part 3 of 5: Watch this video to learn more as Dr. Fischer demonstrates surgical techniques using the DePuy Synthes Variable Angle Locking Hand System in this five-chapter series. In this video watch Dr. Fischer demonstrate the surgical application of the First Metacarpal Plate, Lateral approach featured in the system.Implants Date: Hospital: Surgeon: Procedure: Case Information (eg, Case ID): MODULAR MINI FRAGMENT LCP® SYSTEM 2.0 mm, 2.4 mm and 2.7 mm Implants Inventory Control Form0X.211.201 – X-Plates 2.4/2.7, VA locking 0X.211.204 (Extra-Small, Small, Medium, Large) For full ordering information and product details please refer to technique guide “Variable Angle LCP Forefoot/Midfoot System 2.4/2.7” 036.001.232. The general fusion plates consist of variable angle cortex screws, and a compression feature to tive ...DePuy Synthes plating systems commonly used for Shoulder, Clavicle, Elbow, Proximal Tibia, Distal Tibia and Distal Fibula anatomies, an average cost to wash per tray of $47.72, assumes 5 trays washed per set and average of 2.25 sets per procedure, total affected case volume of 260 cases per year at a facility. 3.The SYNTHES® Modular Hand System provides implants and instruments specifically designed for fractures, replantations and reconstruction of the hand. Features. Modules …The DePuy Synthes Cannulated Compression Headless Screws are indicated for use in bone reconstruction, osteotomy, arthrodesis, joint fusion, fracture repair, and fracture fixation of bones appropriate for the size of the device. Screws are intended for single use only. Contraindications The implant should not be used in a patient who has

Pixelmon is a fan-created modification in “Minecraft.” This mod is heavily based on the Pokemon games, and it is designed to allow players to find, capture and train various Pokemo...Pre-drill the hole for a 1.5 mm cortex screw with the 1.1 mm drill bit using the double drill guide. To drill a gliding hole, use the 1.5 mm drill bit with the double drill guide. (1) To adjust the plate position, a 1.5 mm cortex screw can be inserted in the non-threaded elongated hole (in T-, Y- and Condylar Plate). Variable Angle Locking Hand System Titanium 1.3 mm Titanium Locking Plates* 04.130.150 Straight Plate, 6 holes 04.130.151 Straight Plate, 12 holes 04.130.152 T-Plate, 3 holes head, 5 holes shaft 04.130.153 Y-Plate, 3 holes head, 5 holes shaft 04.130.154 Phalangeal Base Plate, 2 holes head, 5 holes shaft 04.130.156 Phalangeal Head Plate, right Synthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J10176-B 3/13 2.4 mm/2.7 mm Titanium VA-LCP First MTP Fusion Plates Small Inventory Control Form 2.4 mm/2.7 mm Titanium VA-LCP Forefoot/Midfoot Plating System 04.211.230 0° right 04.211.231 0 ...Instagram:https://instagram. aita for feeling left out of my step child's pregnancymi deh yah yuh know meaningkia soul code p0420manatee dmv appointment Mar 15, 2561 BE ... Part 2 of 5: Watch this video to learn more as Dr. Fischer and Dr. Richard demonstrate the approach when using the DePuy Synthes Variable ...components necessary for the DePuy Synthes Variable Angle Locking Hand System. DePuy Synthes Companies are dedicated to improving patient care. System Snapshot x Extensive system of anatomically precontoured plates x First to the market with 1.3 mm locking screws for hand plating1 x Forceps that aid in fracture reduction and lag screw application isaiah torres autopsy photoshenrico county juvenile detention center Learn more on the 1.5 mm LCP® Modular Mini Fragment System by DePuy Synthes, with a variety of plate styles to address a range of small bone fractures.02.118.408 7 holes, right 02.118.409 7 holes, left. 2.7 mm Variable Angle LCP Distal Tibia T-Plates. 02.118.306 4 holes 02.118.307 6 holes. Available nonsterile or sterile-packed. Add “S” to catalog number to order sterile product. Inventory Control Form. 2.7 mm/3.5 mm Variable Angle LCP Ankle Trauma System. ford gumball machine parts The VariAx Hand Locking Module is a plating system offers the benefits of variable locking plates and screws for and 2.3mm implant sizes. The Profyle Hand Standard Plating Module builds upon the strong foundation of the Profyle, which has been in the market since 1994. It is a non-locking plate and screw module for 1.2mm, 1.7mm and.The Mini External Fixator is made up of the following key components: Holding clamps available in 2 sizes. 3.0 mm / 3.0 mm and 3.0 mm / 4.0 mm connecting clamps. Threaded, trocar tip Kirschner wires available in 2 sizes. Angled connecting bar.